위 경우 해결방법은 IMM업데이트 입니다.
최신버전으로 업데이트 하시면 자동으로 드라이버 업데이트 됩니다.
원문:
4.4 Installing the RNDIS/CDC USB network device driver & the Integrated Management Module (IMM) firmware
To install the RnDis\CDC USB network device driver & the Integrated Management Module (IMM) firmware, complete the following steps:
- Go to Software and device drivers
- Click System x3650 M2
- Select your machine type from the Type drop down menu.
- Select "Windows Server 2003" or "Windows Server 2003 x64" from the Operating system drop down menu.
- Select "Integrated Management Module (IMM)" from the Refine Results drop down menu and click Go.
- Locate and download the firmware update utility for the Integrated Management Module (IMM).
- Locate and download the README (.txt) file for the Integrated Management Module (IMM).
- Follow the instructions in the README (.txt) file to install the Integrated Management Module (IMM).
Note: The RnDis\CDC USB network device driver automatically installs prior to the IMM firmware and clears the unknown device message as part of this total installation.
Integrated Management Module firmware update v1.07 for Windows - IBM System x Servers
Supported systems:
- System x3200 M3 (7327, 7328)
- System x3250 M3 (4251, 4252, 4261)
- System x3400 M2 (7836, 7837)
- System x3500 M2 (7839)
- System x3550 M2 (4198, 7946)
- System x3650 M2 (4199, 7947)
- System x iDataPlex dx360 M2 server (6380, 7321, 7323)
IMPORTANT: This firmware update contains changes to permit servers to be powered on sooner after plugging them into AC power. Before installing UEFI with firmware that supports the early power on changes, be sure to update the IMM with this firmware version.
Version 1.04 - Build ID: YUOO24I
Problem(s) Fixed:
- This is a critical update for x3550 M2 and x3650 M2. It corrects a possible problem that can occur when adding options such as memory, hard drives, and Central Processing Units (CPUs), and makes the system may become unresponsive. In some cases the server cannot power on again, or network connectivity
to the Integrated Management Module is not possible. The problem may also occur when rebooting the IMM while the system is powered on with certain hardware configurations. - Replaced the ibm_rndis_server_os.inf and device.cat in the IMM firmware update package for Windows. The new files are used to workaround a potential performance issue when the IMM's Ethernet over USB is enabled