팬에서 소음이 심할경우 팬 케이지를 다시 리싯 해야합니다
그럴경우 좀 어려움이 있는데요
동영상을 보고 쉽게 따라해보시기 바랍니다.
팬케이지 제거 동영상
https://www-947.ibm.com/support/entry/myportal/docdisplay?lndocid=MIGR-5082364
Text from the audio portion of the Fan Cage Assembly removal movie
To remove the Fan Cage Assembly:
Remove the Side Cover:
- Turn off the server and peripheral devices, and disconnect all power cords and external cables.
- Unlock the side cover if required, press the cover-release latch down while rotating the top edge of the cover away from the server and then lift the cover off the server and set it aside.
Remove the Hot-swap Power Supply:
- Disconnect the power cord from the power supply.
- While pressing the release latch to the left, pull the power supply out of the bay.
- Use the same procedure to remove the second power supply if required.
- Place the system on its right side. This is the recommended Service Position
Remove the Air Baffle:
- Lift the power-supply cage handle and then rotate the power-supply cage assembly up until latched in the service position.
- Press the air baffle release latch and then lift the air baffle from the serve
Remove the Fan Cage Assembly:
- Press the fan cage release latches toward the sides of the server. The fan cage will lift up slightly when the release latches are fully open.
- Grasp the assembly and lift it out of the server.
For specific instructions for the removal and installation of hardware.
팬케이지 설치 동영상
https://www-947.ibm.com/support/entry/myportal/docdisplay?lndocid=MIGR-5082365
Text from the audio portion of the Fan Cage Assembly installation movie
To install the Fan Cage Assembly:
- Place the fan-cage assembly into the server, using the guides on the fan cage and the release latches for alignment and press in until latched in place.
Note: Before installing the Fan Cage assembly insure that all cables are routed correctly in there retainers.
Install the Air Baffle:
- Place the air baffle into the server using the positioning pins on the air baffle and the locating holes in the server and fan-cage assembly for alignment, and then press down until latched in place.
- Press the locking tab to release the power supply cage and then rotate the cage into the server and lower the handle.
Note: use care to ensure that the power cables are routed so they are not pinched when closing the cage.
- Improper routing, as shown, here will cause damage to the cables.
- Return the server to its normal operating position.
Install the Hot-swap Power Supplies:
- Slide the Power Supply into the bay until secured by the latch.
- Use the same procedure to install the second power supply if required.
- Connect the power cord to the power supply.
Install the side Cover:
- Position the channel on the cover over the rail on the bottom edge of the chassis..
- Rotate the cover toward the chassis and then press down on the cover release latch and close the cover.
- Lock the side cover if required.
For specific instructions for the removal and installation of hardware.