위 오류 발생시에 대처 방법
ROM이 부족할 경우 나오는 문제입니다.
PCI카드가 꼽혀있을때 나오는거지요
롬 영역을 늘려줍니다.
ROM이 부족할 경우 나오는 문제입니다.
PCI카드가 꼽혀있을때 나오는거지요
롬 영역을 늘려줍니다.
There are several workarounds that can correct this problem:
- Disable some of the PCI components during boot.
- Change the PCI boot device priority.
- Disable ROM execution of some of the devices. This can be achieved using either F1 BIOS setup or by means of an optional Remote Supervisor Slimline Adapter II (RSA 2 slimline) if installed.
- Disable PXE boot on the onboard network adapters by entering F1 Setup and disabling "Planar Ethernet PXE/DHCP" from Start Options.
There are several workarounds that can correct this problem:
- Disable some of the PCI components during boot from the "F1" BIOS Setup Menu.
or
- Change the PCI boot device priority from the "F1" BIOS Setup Menu.
Disabled "Enable Ethernet ROM Execution".
- Go into Setup
- Select Start Options
- Set "Enable Ethernet ROM Execution" to Disable
http://www-947.ibm.com/systems/support/supportsite.wss/dosearch?searchtype=1&brandind=5000008&q=1801+pci&v=16&en=utf&lang=en&cc=zz
위 주소 참고 하시면 됩니다